The C-534BX4 is the perfect complement to the light commercial wall hydrant it protects. This unique stainless steel box product can be installed in the structure independently of the valve. Additionally, it adds flexibility as the box can be installed by a brick mason or general contractor and the plumber can come later to install the valve through the front of the box and plumb it when it is convenient for their schedule.
Finally, this box has a hinge that is designed to stay open when the consumer is using the valve. It won’t flop down on the hose or get in the way on the side of the box.
Product Support
PRIER has been manufacturing the C-534 Freezeless Hydrant since 1992. It is a simple operating product that is fairly simple to repair. The C-534 Freezeless Hydrant drains with the hose attached and under pressure. To accomplish this, there is a bypass assembly in the hydrant. Possible Repair Issues for the C-534 Freezeless Wall Hydrant include:
1. When the water is running, water leaks out from behind the handle
When the C-434/534 Hydrant is turned into the "off" position, the water in the valve will drain out behind the packing nut. If water leaks from behind the packing nut during operation, the o-ring or u-cup bypass has been damaged and needs to be replaced.
To determine which of the two styles you have, the stem needs to be removed from the valve to identify the bypass type. The bypass will be on the stem, near the handle end.
Current Style-O-Ring:
Old Style-U-Ring:
2. The hydrant drips after shut off
C-434KT-902 Stopper and Pin Kit (with tool and o-ring)
3. The operating key is missing from my hydrant
The required part number is C-108KT-808.
C-108KT-808 Operating Key
4. How do I convert the hydrant to handle operated?
Contents of this kit are as follows:
5. The stem end is damaged and I cannot operate the freezeless hydrant
To determine the proper replacement stem, you need to determine the following:
1. Overall length (OAL) of the stem, from tip to brass tip. Do not include the rubber bibb washer in this measurement.
2. Using the acquired dimensions, determine which stem is required from the chart below:
The following stems are for the C-434/C-534 Freezeless Hydrant (manufactured 2007-present):
The following stems are for the C-434/C-534 Freezeless Hydrant (manufactured pre-2007):
6. Water is leaking from the holes by the hose thread
The rubber washer inside the vacuum breaker has failed and needs to be replaced. This is accomplished by unthreading the vacuum breaker from the body of the hydrant and replacing the internals. The vacuum breaker is sealed to the body with a body sealant and may require heat to break loose.
The parts required for this is a C-434KT-906 Vacuum Breaker Replacement Kit
Installation Instructions:
To repair the vacuum breaker on any of the above items, it first needs to be removed from the valve. The vacuum breaker is sealed to the valve and needs to be heated with a torch to be removed. Once it is removed you can reinstall the new parts in the order as shown above.
7. I need a complete rebuild kit
C-534KT-907 Overhaul Kit
Contents of this kit are as follows: